Corrosion, cracks and wall loss rarely announce themselves. By the time a leak appears, the damage has usually been building for months. Non-destructive testing (NDT) finds those problems early, without cutting, drilling or taking equipment apart.

If you look after plant, pipework, tanks or steel structures, here’s a plain guide to the main NDT methods, what each one finds, and how to choose.

What is NDT?

NDT is a group of inspection methods that check the condition of a material or weld without damaging it. The equipment stays in one piece, and often stays in service while you inspect it.

Sites use it at three main stages:

  • During fabrication, to check welds and materials before they go into service
  • In service, to monitor corrosion, erosion and cracking over time
  • Before decommissioning or reuse, to confirm what condition an asset is in

Visual inspection (VT)

Every inspection starts here. A trained inspector looks for corrosion, coating breakdown, leaks, distortion, damaged insulation and cracking, using tools such as torches, mirrors, gauges and cameras.

It’s quick and low cost. Even better, it often tells you where to use the other methods.

Ultrasonic testing (UT)

Ultrasonic testing sends high-frequency sound into the material and measures the echo. Inspectors use it to:

  • Measure wall thickness, which is the standard way to track corrosion and erosion on pipes, tanks and vessels
  • Find internal flaws, such as laminations, inclusions and cracks inside welds

A big advantage is that you only need access to one side. As a result, you can usually check a pipe or tank while it’s full and running.

Magnetic particle inspection (MPI)

MPI magnetises the part and applies fine iron particles. Where there’s a crack, the magnetic field leaks out and the particles gather to show it.

  • Finds surface and near-surface cracks
  • Works only on ferromagnetic materials, such as carbon steel
  • A common choice for welds, lifting equipment and structural steel

Dye penetrant inspection (DPI)

First, the inspector applies a coloured or fluorescent liquid to a clean surface. It seeps into any crack. Next, they wipe off the excess, and a developer draws the dye back out to show the defect.

  • Finds surface-breaking defects only
  • Works on most non-porous materials, including stainless steel and aluminium, where MPI won’t work
  • Simple and portable, so it’s useful in awkward locations

Eddy current inspection (ET)

Eddy current testing uses an electromagnetic probe to detect changes in the material’s surface. It can find surface cracks, sometimes through paint or coatings. Inspectors also use it to measure coating thickness. Because you often don’t need to remove the coating, it saves preparation time.

Which method do you need?

What you want to find Usual method
General condition, leaks, coating damage Visual
Wall thinning from corrosion or erosion Ultrasonic thickness
Internal flaws in welds or plate Ultrasonic
Surface cracks in carbon steel MPI
Surface cracks in stainless steel or aluminium Dye penetrant
Surface cracks without removing paint Eddy current

In practice, most inspection programmes use a mix. For example, an inspector might start with a visual survey, then take UT thickness readings on corroded areas and use MPI on critical welds.

Baseline surveys and repeat inspections

On its own, one set of readings tells you where you are. However, repeat readings at the same points tell you how fast things are changing. That’s why a baseline survey is so useful: it gives you a record to compare against, so you can plan repairs before something fails rather than after.

Who should carry out NDT?

NDT results are only as good as the person taking them. In the UK, most NDT technicians hold certification to ISO 9712, often through the PCN scheme, at Level 1, 2 or 3 for each method. So ask your contractor which methods and levels their technicians hold.

NDT with AIC

AIC carries out visual, ultrasonic, magnetic particle, dye penetrant and eddy current inspection, including in-service inspections and baseline surveys. Combined with our rope access teams, we can inspect almost anywhere on an asset without full scaffolding. If we find problems, we can also help put them right, from corrosion under insulation repairs to blasting and painting.

See our NDT inspection services, or call 01642 689587 or email sales@aic-industrial.co.uk.