A leaking pipe or a corroded tank doesn’t always wait for your next planned shutdown. Cutting out and replacing the damaged section usually means isolating the line, draining it, getting a hot work permit and bringing in welders. That all costs time and lost production.

In many cases, there’s another option: a cold-applied polymer repair, carried out while the equipment stays in service. Belzona is one of the best-known names in this field, and AIC uses Belzona systems for in-service repairs on industrial sites.

What is a Belzona repair?

Belzona makes polymer repair composites and coatings. They’re mixed on site, applied by hand, and cure to form a hard, bonded repair that rebuilds lost metal, seals leaks and protects against further corrosion.

Because they’re applied cold, there’s no welding and no hot work. That makes them especially useful on sites where hot work is restricted or would need a shutdown.

What can be repaired?

Typical in-service repairs include:

  • Pipework: pinhole leaks, weeping joints and areas of wall loss caused by corrosion
  • Tanks and vessels: corroded walls, floors and roofs
  • Pumps and valves: worn casings, impellers and seats, rebuilt to shape
  • Flanges: pitted or damaged faces rebuilt and re-machined
  • Heat exchangers: tube sheets and end plates protected against erosion and corrosion
  • Concrete: bunds and floors repaired and protected

How a live leak repair works

Every job is different, but a typical in-service leak repair follows these steps:

  1. Assess: check the line contents, pressure and temperature, and confirm a polymer repair is suitable.
  2. Stop the leak: a fast-setting product is used to plug or seal the active leak.
  3. Prepare the surface: the area around the defect is cleaned and roughened so the repair can bond. Some Belzona products are designed to bond to wet or oily surfaces.
  4. Apply the repair: the main repair compound is applied, often with reinforcement tape or a composite wrap to restore strength.
  5. Cure and inspect: the repair is left to cure, then checked before the area is signed off.

Where a section of pipe needs its strength restored, an engineered composite wrap can be designed to recognised pipe repair standards such as ISO 24817 and ASME PCC-2.

The benefits

  • No shutdown in many cases: the plant keeps running while the repair is made
  • No hot work: safer on live sites and no fire watch needed
  • Fast: many repairs are completed in hours, not days
  • Long lasting: a properly applied repair also protects against further corrosion
  • Less disruption: no cutting out, no new spools, fewer trades on site

When it isn’t the right answer

Polymer repairs are a powerful tool, but they aren’t right for every job. Very high pressures or temperatures, certain chemicals, or severe structural damage may still need a mechanical repair or replacement. A good contractor will tell you honestly which option is right, and whether a repair is permanent or a temporary fix until your next shutdown.

Spotting problems early

The earlier corrosion is found, the easier and cheaper it is to fix. Regular inspection helps, including NDT inspection to measure wall thickness and checks for corrosion under insulation, where damage is hidden from view.

Why use AIC

AIC carries out Belzona repairs alongside insulation, cladding, blasting and painting, NDT and rope access. That means one team can inspect the damage, make the repair, re-coat the area and put the insulation back, even at height.

Got a leak or corrosion problem that can’t wait for a shutdown? Call 01642 689587 or email sales@aic-industrial.co.uk, and we’ll come back with advice and a quote, usually within 2–3 working days.